R32 On/Off Cooling Only
Air Conditioner
Cassette / High ESP Duct
Reliable Cooling
Under 46°C
Constant Air Volume
Dual Direction
Of Drainage
360° Surround
Air Outlet
High ESP
Up To 200 Pa
200Pa
WiFi App + OTA
Gentle Air Built-in Water Pump
46
Catalogue
02-03
Introduction Of
TCL CAC
04
New R32 Air
Conditioner Features
12-15
Product
Parameters
09-11
Intelligent
Control
05-06
360° Air
Outlet Cassette
07-08
D1 series High Static
Pressure Duct Units
R32 On/Off Cooling Only Air Conditioner
The Creative Life
BUSINESS OVERVIEW
TCL is a leading global tech brand in display panels, TVs, home comfort and mobile devices. Founded
in 1981, TCL operates its manufacturing and R&D centers worldwide and has products and services in
160+ countries.
At TCL, we are dedicated to improving people's lives and experiences with our innovative technology.
Our products and services aim to solve problems, bring joy to families and friends, and create a safer
and healthier world. We aspire to inspire and empower people to pursue greatness in their lives.
Air Conditioners & HVAC
Refrigeration & Laundry Appliances
Homa Refrigerators
Large-size Display & Internet Business
Mid & Small-size Display Terminals
Smart Commercial Display Terminals
Smart Connectivity
Smart Home
Photovoltaic Technology
Smart Home Appliances
Display Business
Innovative Businesses
R32 On/Off Cooling Only Air Conditioner
02 Top 11 Manufacture AC Bases Worldwide
Brazil
China
Indonesia
Brazil Factory
Indonesia Factory
OUR VISION: To become a global leader in green energy and healthy air management solutions.
OUR MISSION: Make it easier for you to enjoy healthy and green life brought by air.
Since
1999
20+ million sets
Annual sell (2025)
5
R&D center
15,000+
Employees
Sell to 160+
Nations & Regions
TCL AC 02
OUR MISSION: Make it easier for you to enjoy healthy and green life brought by air.
R32 On/Off Cooling Only Air Conditioner
03
Zhongshan No.1 Factory
Bulk Parts Factory
Commercial Factory
Zhongshan No.2 Factory
Rechi Compressor Factory
Wuhan Factory
Guangzhou Factory
Wankezi Factory
Jiujiang Factory
03
Capacity
3,000,000 Sets per year
Annual Output Value:
¥5.8 billion
Digital Production
Lines:9
Facility Size
50 acres
9
Strong R&D Capabilities
Smart Production Technology
R&D Personnel:
300+
Proprietary Intellectual
Property: 691 patents
Advanced
Labs: 25
Annual R&D Investment:
Over 400+ million yuan for 3 years
Commercial AC
R32 On/Off Cooling Only Air Conditioner
R32 On/Off Cooling Only Air Conditioner 04 During the operation of the air conditioner, if the
power is cut off then comeagain, the device will work
as the previous mode and setting temperature.Making
operation and maintenance easy and convenient.
Power Off Memory
New R32 Air
Conditioner
Features
Cooling steadily from 18 to 46°C, meet various of
working conditions and scenarios.
Ambient Temperature Range
The pipe length of inverter unit can be up to 50m
and 30m height difference between lDU and ODU,
reducing the limitation on installing location.
Long Pipe Length High Drop
18°C 46°C
The system reliability design allows wide voltage
tolerance of +10%.For example 220~240V/1N units
allow 198 ~ 264V input voltage.
Wide Voltage Tolerance
198V
264V
220V~240V
Standard voltage input
Power off
Restart
26°C
26°C
Long pipe length
High drop
R32 On/Off Cooling Only Air Conditioner
R32 On/Off Cooling Only Air Conditioner
05
Arc louver swing angle, range from 0-85°, send soft air
to any corner of the room easily.
Wide Range Of Swing Angle
Comfortable
360° Air
Outlet Cassette
360°of outlet wind, 2565 micro-hole
soft wind lades to break up the airflow,
making the wind soft and comfortable
to the body.
Round air outlet
Easily adjust the wind speed to suit your needs with
seven gear settings.
7-Speed Wind Control
R32 On/Off Cooling Only Air Conditioner
R32 On/Off Cooling Only Air Conditioner
06 Comfortable
TCL products through the reasonable air circuit design
and 3D fan blade selection, increase the unit airflow and
reduce operating noise, which can be as low as 35dB(A)*.
*For 18k cassette
Take in outdoor fresh air, ensure that the indoor air is
fresh and circulated.
The filter is very easy to disassemble and clean,
keeping the air healthy all the time.
If too much condensate water accumulatesin the
indoor unit, or water pump fails it will alert, to prevent
water overflow.
The Cassette has a built-in water pump, the maximum
lift can reach 1200mm, which is conducive to the
installation of drain pipes.
Low Noise Design
Fresh Air Easy To Clean Filter
Water-Overflow Protection
3D fan blade design
35dB(A)
1200mm Water Pump Lift
07
D1 Series High Static
Pressure Duct Units
Take in outdoor fresh air, ensure that the indoor air is fresh and circulated. Max fresh air volume 100m2
/h.
Fresh air module (optional) Knock-off hole for fresh air
Fresh Air
Delicate fan speed adjustment. To satisfy windsensitive users’ requirement, more comfortable.
Seven Gear Wind Speed
ESP up to 200Pa* supports longer air duct and fits with more installation scenarios.
Fitting Long external duct
10-20M
*Only for 48~60k duct
High ESP
Support both ceiling concealed and floor concealed
installation.
Ceiling & Floor Installation
R32 On/Off Cooling Only Air Conditioner
R32 On/Off Cooling Only Air Conditioner 08 Duct are new designed body of 245mm thickness
which is convenient for concealed installation.
Slim Body 245mm
There are two air return modes to be chosen for engineering
installation: bottom air return and rear air return.
Flexible Air Return Options
bottom air return rear air return
Air return
Air supply
Air return
Air supply
Fan motor automatically adjusts speed according to
wind resistance. To provide stable air volume to rooms.
Constant Air Volume
The integral water pump is in one pieces and easy
for maintenance, with 1200mm high lift.
High Efficiency Water Pump (optional)
The actual drainage lift may vary due to factors such as the diameter of the
drainage pipe, the position of the pipe layout.
The filter panel full of silver ions and activated carbon
will help you filter out most harmful bacteria and ensure
the health of indoor air.
Health Filter (optional)
When piping leaks or system in malfunction, refrigerant
could be recovered and stored in ODU condenser.
Refrigerant Recovery
·Reduce refrigerant leakage
·Reduce pollution
·Save cost
R32 On/Off Cooling Only Air Conditioner
09
R32 DC Inverter Air Conditioner (SEA Cooling Only)
Empowering commercial buildings & industrial parks, building an integrated control + energy supervision + split billing
IOC Platform
01.Product Overview
02.Key Features
03.Flexible Deployment Modes 04.Powerful Access Capacity (Single Gateway)
Intelligent
Control
Management Layer
(Software platform)
Control Layer
(Smart gateway)
Device Layer
(Air conditioning equipment)
Cassette Duct
Smart Schedule
Management
Individual Billing
System
Data O&M&
Fault Analysis
Comprehensive
Centralized Control
Remote Monitoring VRF/
LCAC / Modular, Batch
On/Off, group management.
Cloud-based Local-based
VRF: 1024 Indoor Units
LCAC: 255 Units
Modular: 247 Sets
Timed automatic
operation, ordinary /
priority schedule settings.
VRF professional billling,
tenant full lifecycle
management, periodic billing
*Billing only available for VRF system
Real-time energy data
collection, automatic curve
generation, fault alarm
statistics
04.Powerful Access Capacity
Control Layer
(Smart gateway)
R32 On/Off Cooling Only Air Conditioner
R32 On/Off Cooling Only Air Conditioner 10 Various of controllers meets different users’ demand. Including wired controller, remote controller, APP control,
central control and BMS control.
Multiple Control Modes
Central Controller Basic routine control, group management, schedule management, abnormal operation monitoring,
energy-saving strategy formulation, and fault tracing.
IOC The powerful IOC (Integrated Operation Center) integrated control on LCAC, VRF and chillers, cloud visiting,
user permissions allocate, allowing AC managers to control anytime, anywhere (with internet ).
3rd BMS Control The Modbus port on the PCB, allows up to 255 AC units connecting with the 3rd party BMS
(BuildingManagement System).
Wifi Module/
WiFi Controller These optional WiFi accessories allows smart-phone control via TCL APP or TUYA APP.
Voice Controller Off-line speech recognition technology allows user control units by just speaking
(Only English now, partial models available)
AC Detector This intelligent detector is used for aftersales service, with portable size a Service Assist APP, to inquire
parameters quickly and troubleshooting.
R32 On/Off Cooling Only Air Conditioner
11
ESP can be set on wired controllers instead of
setting on PCB. Convenient for installation.
Reserved port on board to wiring with room card/fire
alarm/window signal.
ESP Adjust On Wired Controller Dry Contact (optional)
Fire Alarm
Room card
Window
signal
WiFi Control & OTA (optional)
The same air conditioner can be controlled by
two wire controllers by setting the primary and
secondary wire controllers, you can adjust the most
comfortable temperature for your child without
going to the child's room.
Wire Control 1 Wire Control 2
Compatible with the 3rd party zoning controller,
realize independently adjustment for each room.
Air-Zone Solutions Double Wired Controller >>>>>>>>>>>>> >>>>>>>>>>>>>
>>
>>
>>
>>
>>>>> > >>> >>>> >>>>>>>>>>>>>
Air distributor
20°C 21°C 22°C 23°C >>>>>>>>>
·Remotely turn on/off and set
schedule or timer.
·Monitor running datas and
operation history.
·The air-conditioner upgrades on
the air via WiFi and APP.
R32 On/Off Cooling Only Air Conditioner 12 Optional Accessories
Wired Controller
86J1
(Duct Standard)
86V1
(Voice controller)
86B1
(Built-in WiFi)
120
Water Pump
(Duct Optional)
Gentle Wind Panel
(Cassette Optional)
Condenser
Remote Controller
Central Controller
Gateway
(For IOC or BMS)
Detector
(For aftersale)
WiFi Control
(Optional)
APP
52E 66E 85T
(Cassette Standard)
Golden Fin(optional)
Blue Fin
Note: Voice controls incompatible with cassette.
R32 On/Off Cooling Only Air Conditioner
13
GD TCL INTELLIGENT HEATING & VENTILATING EQUIPMENT CO.,LTD.
Address: No.7 Yuanlin Road, Nantou, Zhongshan, Guangdong, PR China
Web : cac.tcl.com E-mail : hvac@tcl.com
TCL CAC TCL CAC TCL CAC HVAC-TCL TCL- CAC
V26.04.02